Home Precision Environment Aerosol Conditioning DIL 553 High-Flow Static Dilution System
DIL 553 Aerosol Dilution System product image thumbnail
Topas GmbH Aerosol Dilution Systems

DIL 553 High-Flow Static Dilution System

Manual static aerosol dilution system for 56.6 or 50 L/min flow, configurable for 1:100 or 1:10 dilution in high-flow cleanroom and filtration measurements.

Dilution factor
1:100; optional 1:10
Aerosol flow
56.6 L/min; optional 50
Setting
Manual
Pressure drop
2.9 kPa
High flow 56.6 / 50 L/min 1:100 or 1:10 Manual
ISO 14644-3 VDI 2083 VDI 3491-6 VDI 3491-15

Model Overview

Model Configuration Primary use Selection note
DIL 553 1:100; optional 1:10; 56.6 L/min; optional 50 Manual static aerosol dilution system for 56 Select DIL 553 for high-flow aerosol dilution at 56.6 or 50 L/min.

Key Features

Defined and reproducible dilution

Reduces aerosol particle concentration by a specified ratio while retaining the particle-size distribution of the sampled aerosol.

Capillary and HEPA-bypass principle

A small capillary flow retains the original particle concentration while particles are removed from the larger bypass flow before both streams are recombined.

Stable operation

Designed to provide a consistent dilution ratio during changing operating conditions in cleanroom, filter-test and aerosol-measurement workflows.

No auxiliary compressed-air supply

The passive flow arrangement uses the downstream instrument or process flow, avoiding a separate dilution-air supply for normal operation.

Overpressure and underpressure capability

Suitable for integration in measurement lines that operate under positive or negative pressure within the specified counterpressure limits.

Low-maintenance construction

Uses a compact fluidic layout with a HEPA-filtered bypass and requires only routine inspection and service of the flow path and filter elements.

Technical Specifications

Parameter Unit Value / Description
DILUTION PERFORMANCE
Purpose Dilution of aerosols
Dilution factor 100; optional 10
Aerosol volumetric flow rate L/min 56.6; optional 50
Setting method Manual
Inlet condition Non-diluted aerosol
Outlet condition Diluted aerosol
CONNECTIONS & OPERATING CONDITIONS
Power supply 12 V DC, 30 mA
Hose connector mm Ø 8, optional Ø 10
Pressure drop kPa 2.9
Environmental temperature °C 10–50
PHYSICAL
Dimensions (W × H × D) mm 110 × 160 × 300
Weight kg 1.5

Specifications follow the current Topas GmbH product information reviewed for this page. Confirm the final configuration, accessories and calibration documentation at quotation stage.

Applications

Verification of cleanroom test aerosols

Reduces high upstream challenge-aerosol concentrations to a range suitable for optical particle counters during cleanroom and clean-air-device testing.

Laminar-flow and safety-cabinet acceptance

Supports acceptance measurements on laminar-flow boxes, work benches, safety cabinets and smaller cleanroom installations.

Filter separation-efficiency measurement

Extends the usable concentration range of particle counters in upstream and downstream filter-efficiency measurements.

Highly concentrated aerosol analysis

Conditions concentrated aerosol samples before particle counting to reduce coincidence-related measurement errors.

Aerosol research

Provides a defined dilution stage for experimental aerosol generation, transport and particle-size-distribution studies.

Measurement-range extension

Allows particle-measurement instruments to analyse aerosol concentrations that would otherwise exceed their operating range.

Similar Products